Sunday, May 4, 2014

TENSILE SHADES

TENSILE SHADES

byEr. Vishant Chandrawar 
(B.E. Civil)
Manama, Kingdom of Bahrain


tensile structure is a construction of elements carrying only tension and no compression or bending. The term tensile should not be confused with tensegrity, which is a structural form with both tension and compression elements. Tensile structures are the most common type of thin-shell structures.
Most tensile structures are supported by some form of compression or bending elements, such as masts (as in The O2, formerly the Millennium Dome), compression rings or beams.

Another definition:

What is a tension structure or tensile structure?

As per the Lightweight Structures Association (LSA), a division of the Industrial Fabrics Association International, a tension structure ortensile structure is a structure that is characterized by a tensioning of the fabric or pliable material system (typically with wire or cable) to provide the critical structural support to the structure.

Tension structures are fabricated as permanent or temporary canopy structures for commercial or public assembly, temporary event structures, modular industrial construction and landscape artwork.  This unique fabric canopy strives for a light and airy look by minimizing the amount of framing and utilizing the strength of the fabric to help support the stability and equilibrium of the structure.

Fabric tensioned structures are typically used as a lightweight roof, protective cover, shelter, skylight, advertisement and/or identification for stadiums, arenas, shopping malls, amphitheaters, bandshell, stage cover, tents, and shade structures for airport and transportation depots.

Tension structures utilize technical fabric roof membranes, a combination of catenary cables and clamping systems, and a minimal amount of framing to create proportionally lightweight structures capable of spanning great distances. Tensile membranes are available in exterior grade vinyl and woven fabrics and Teflon™ coated fiberglass. These translucent tensioned membrane structure fabrics carry from seven to twenty year warranties.
tensile membrane structure is most often used as a roof, as they can economically and attractively span large distances.

How much does a tension structure cost?

How much does a tension structure cost?


Today's prices for engineered fabric tension structures are in the neighborhood of $120 per square foot. Every design is unique and prices will vary depending upon the overall complexity of project, size, design, engineering calculations involved, scope of work, municipal codes & permit requirements, time tables and other site logistics.

Upon full project discovery and disclosure, our professional staff will work with you to produce a fixed price for required engineering certifications. Once engineering certifications and materials are defined, a firm price will be provided for project management, manufacturing and installation services.

With over 69-years of custom fabric and metal fabrication experience, Eide Industries, Inc. will provide ideal solutions for your project's engineering design certifications, project management, manufacturing and installation needs.

History

his form of construction has only become more rigorously analyzed and widespread in large structures in the latter part of the twentieth century. Tensile structures have long been used in tents, where the guy ropes and tent poles provide pre-tension to the fabric and allow it to withstand loads.
Russian engineer Vladimir Shukhov was one of the first to develop practical calculations of stresses and deformations of tensile structures, shells and membranes. Shukhov designed eight tensile structures and thin-shell structures exhibition pavilions for the Nizhny Novgorod Fair of 1896, covering the area of 27,000 square meters. A more recent large-scale use of a membrane-covered tensile structure is the Sidney Myer Music Bowl, constructed in 1958.
Antonio Gaudi used the concept in reverse to create a compression-only structure for the Colonia Guell Church. He created a hanging tensile model of the church to calculate the compression forces and to experimentally determine the column and vault geometries.
The concept was later championed by German architect and engineer Frei Otto, whose first use of the idea was in the construction of the West German pavilion at Expo 67 in Montreal. Otto next used the idea for the roof of the Olympic Stadium for the 1972 Summer Olympics inMunich.
Steady technological progress has increased the popularity of fabric-roofed structures. The low weight of the materials makes construction easier and cheaper than standard designs, especially when vast open spaces have to be covered.

Types of structure with significant tension members[edit]

Linear structures[edit]

Three-dimensional structures[edit]

Surface-stressed structures[edit]






Cable and memedit]

The World First steel membrane roof and lattice steel Shell in the Shukhov Rotunda,Russia, 1895

Membrane materials[edit]

Common materials for doubly curved fabric structures are PTFE-coated fiberglass and PVC-coated polyester. These are woven materials with different strengths in different directions. The warp fibers (those fibers which are originally straight—equivalent to the starting fibers on a loom) can carry greater load than the weft or fill fibers, which are woven between the warp fibers.
Other structures make use of ETFE film, either as single layer or in cushion form (which can be inflated, to provide good insulation properties or for aesthetic effect—as on the Allianz Arena in Munich). ETFE cushions can also be etched with patterns in order to let different levels of light through when inflated to different levels. They are most often supported by a structural frame as they cannot derive their strength from double curvature.

Cables[edit]

Simple suspended bridge working entirely in tension
Cables can be of mild steelhigh strength steel (drawn carbon steel), stainless steelpolyester or aramid fibres. Structural cables are made of a series of small strands twisted or bound together to form a much larger cable. Steel cables are either spiral strand, where circular rods are twisted together and "glued" using a polymer, or locked coil strand, where individual interlocking steel strands form the cable (often with a spiral strand core).
Spiral strand is slightly weaker than locked coil strand. Steel spiral strand cables have a Young's modulusE of 150±10 kN/mm² (or 150±10 GPa) and come in sizes from 3 to 90 mm diameter. Spiral strand suffers from construction stretch, where the strands compact when the cable is loaded. This is normally removed by pre-stretching the cable and cycling the load up and down to 45% of the ultimate tensile load.
Locked coil strand typically has a Young's Modulus of 160±10 kN/mm² and comes in sizes from 20 mm to 160 mm diameter.
The properties of the individuals strands of different materials are shown in the table below, where UTS is ultimate tensile strength, or the breaking load:
E (GPa)UTS (MPa)Strain at 50% of UTS
Solid steel bar210400–8000.24%
Steel strand1701550–17701%
Wire rope1121550–17701.5%
Polyester fibre7.59106%
Aramid fibre11228002.5%

Structural forms[edit]

Air-supported structures are a form of tensile structures where the fabric envelope is supported by pressurised air only.
The majority of fabric structures derive their strength from their doubly curved shape. By forcing the fabric to take on double-curvature [1] the fabric gains sufficientstiffness to withstand the loads it is subjected to (for example wind and snow loads). In order to induce an adequately doubly curved form it is most often necessary to pretension or prestress the fabric or its supporting structure.

Form-finding[edit]

The behaviour of structures which depend upon prestress to attain their strength is non-linear, so anything other than a very simple cable has, until the 1990s, been very difficult to design. The most common way to design doubly curved fabric structures was to construct scale models of the final buildings in order to understand their behaviour and to conduct form-finding exercises. Such scale models often employed stocking material or tights, or soap film, as they behave in a very similar way to structural fabrics (they cannot carry shear).
Soap films have uniform stress in every direction and require a closed boundary to form. They naturally form a minimal surface—the form with minimal area and embodying minimal energy. They are however very difficult to measure. For large films the self-weight of the film can seriously and adversely affect the form.
For a membrane with curvature in two directions, the basic equation of equilibrium is:
w = \frac{{t_1}}{{R_1}} + \frac{{t_2}}{{R_2}}
where:
  • R1 and R2 are the principal radii of curvature for soap films or the directions of the warp and weft for fabrics
  • t1 and t2 are the tensions in the relevant directions
  • w is the load per square metre
Lines of principal curvature have no twist and intersect other lines of principal curvature at right angles.
geodesic or geodetic line is usually the shortest line between two points on the surface. These lines are typically used when defining the cutting pattern seam-lines. This is due to their relative straightness after the planar cloths have been generated, resulting in lower cloth wastage and closer alignment with the fabric weave.
In a pre-stressed but unloaded surface w = 0, so \frac{{t_1}}{{R_1}} = -\frac{{t_2}}{{R_2}}.
In a soap film surface tensions are uniform in both directions, so R1 = −R2.
It is now possible to use powerful non-linear numerical analysis programs (or finite element analysis) to formfind and design fabric and cable structures. The programs must allow for large deflections.
The final shape, or form, of a fabric structure depends upon:
  • shape, or pattern, of the fabric
  • the geometry of the supporting structure (such as masts, cables, ringbeams etc.)
  • the pretension applied to the fabric or its supporting structure
It is important that the final form will not allow ponding of water, as this can deform the membrane and lead to local failure or progressive failure of the entire structure.
Snow loading can be a serious problem for membrane structure, as the snow often will not flow off the structure as water will. For example, this has in the past caused the (temporary) collapse of the Hubert H. Humphrey Metrodome, an air-inflated structure in Minneapolis, Minnesota. Some structures prone to ponding use heating to melt snow which settles on them.
Saddle Shape
There are many different doubly curved forms, many of which have special mathematical properties. The most basic doubly curved from is the saddle shape, which can be a hyperbolic paraboloid (not all saddle shapes are hyperbolic paraboloids). This is a double ruled surface and is often used in both in lightweight shell structures (see hyperboloid structures). True ruled surfaces are rarely found in tensile structures. Other forms are anticlastic saddles, various radial, conical tent forms and any combination of them.

Pretension[edit]

Pretension is tension artificially induced in the structural elements in addition to any self-weight or imposed loads they may carry. It is used to ensure that the normally very flexible structural elements remain stiff under all possible loads.
A day to day example of pretension is a shelving unit supported by wires running from floor to ceiling. The wires hold the shelves in place because they are tensioned - if the wires were slack the system would not work.
Pretension can be applied to a membrane by stretching it from its edges or by pretensioning cables which support it and hence changing its shape. The level of pretension applied determines the shape of a membrane structure.

Alternative form-finding approach[edit]

The alternative approximated approach to the form-finding problem solution is based on the total energy balance of a grid-nodal system. Due to its physical meaning this approach is called the Stretched Grid Method (SGM).

Simple mathematics of cables[edit]

Transversely and uniformly loaded cable[edit]

A uniformly loaded cable spanning between two supports forms a curve intermediate between a catenary curve and a parabola. The simplifying assumption can be made that it approximates a circular arc (of radius R).
Catenary cable diagram.svg

The horizontal and vertical reactions :
H = \frac{{wS^2}}{{8d}}
V = \frac{{wS}}{{2}}
By geometry:
The length of the cable:
L = 2R\arcsin\frac{{S}}{{2R}}
The tension in the cable:
T = \sqrt{H^2+V^2}
By substitution:
T = \sqrt{\left(\frac{wS^2}{8d}\right)^2 + \left(\frac{wS}{2}\right)^2}
The tension is also equal to:
T = wR
The extension of the cable upon being loaded is (from Hooke's Law, where the axial stiffness, k, is equal to k = \frac{{EA}}{{L}}):
e = \frac{{TL}}{{EA}}
where E is the Young's modulus of the cable and A is its cross-sectional area.
If an initial pretension, T_0 is added to the cable, the extension becomes:
e = L - L_0 = \frac{{L_0(T-T_0)}}{{EA}}
Combining the above equations gives:
{\frac{{L_0(T-T_0)}}{{EA}}}+L_0 = \frac{{2T\arcsin(\frac{{wS}}{{2T}})}}{{w}}
By plotting the left hand side of this equation against T, and plotting the right hand side on the same axes, also against T, the intersection will give the actual equilibrium tension in the cable for a given loading w and a given pretension T_0.

Cable with central point load[edit]

Point-loaded cable.svg

A similar solution to that above can be derived where:
By equilibrium:
W = \frac{{4Td}}{{L}}
d = \frac{{WL}}{{4T}}
By geometry:
L = \sqrt{S^2 + 4d^2} = \sqrt{S^2 + 4\left(\frac{{WL}}{{4T}}\right)^2}
This gives the following relationship:
L_0 + \frac{{L_0(T-T_0)}}{{EA}} = \sqrt{S^2 + 4\left(\frac{{W(L_0+\frac{{L_0(T-T_0)}}{{EA}})}}{{4T}}\right)^2}
As before, plotting the left hand side and right hand side of the equation against the tension, T, will give the equilibrium tension for a given pretension, T_0 and load,W.

Tensioned cable oscillations[edit]

The fundamental natural frequencyf1 of tensioned cables is given by:
f_1=\sqrt{\frac{{(\frac{{T}}{{m}})}}{{2L}}}
where: T = tension in newtonsm = mass in kilograms and L = span length.

Notable structures[edit]

Rotunda by Vladimir Shukhov Nizhny Novgorod 1896.jpg
Rotunda and rectangular pavilion by Vladimir Shukhov in Nizhny Novgorod 1896.jpg



Credits:
 www.tensileshadeproducts.com
http://en.wikipedia.org/wiki/Tensile_structure
www.tensionstructures.com/